Sign In | Join Free | My himfr.com
Home > Multi Function Calibrator >

Fluke 52120A Transconductance Amplifier tested in full working conditions

Shenzhen Meigaolan Electronic Instrument Co. Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Fluke 52120A Transconductance Amplifier tested in full working conditions from wholesalers
     
    Buy cheap Fluke 52120A Transconductance Amplifier tested in full working conditions from wholesalers
    • Buy cheap Fluke 52120A Transconductance Amplifier tested in full working conditions from wholesalers
    • Buy cheap Fluke 52120A Transconductance Amplifier tested in full working conditions from wholesalers
    • Buy cheap Fluke 52120A Transconductance Amplifier tested in full working conditions from wholesalers
    • Buy cheap Fluke 52120A Transconductance Amplifier tested in full working conditions from wholesalers

    Fluke 52120A Transconductance Amplifier tested in full working conditions

    Ask Lasest Price
    Brand Name : Fluke
    Model Number : 52120A
    Certification : ISO:17025 Accredited Calibration
    Price : Negotiation
    Payment Terms : T/T
    Supply Ability : in stock
    • Product Details
    • Company Profile

    Fluke 52120A Transconductance Amplifier tested in full working conditions


    Fluke 52120A Transconductance Amplifier tested in full working conditions


    Description of Fluke 52120A


    Expand the workload capability of your power and electrical calibrators

    The Fluke Calibration 52120A Transconductance Amplifier supplies dc current up to 100 amps and ac current up to 120 amps, at accuracies to 140 ppm. Using accessory coils, it can generate 3,000 or 6,000 amps. Three 52120As connected in parallel can output up to 360 amps. Inductive drive capability of 1 mH and compliance voltage of 4.5 volts support a wide range of applications.

    52120A performance at a glance

    • Industry-leading amplifier accuracy:
    • - 140 ppm ac (used with 61XXA Electrical Power Standard or 5730A)
    • - 350 ppm ac (used with dc/lf calibrator
    • - 160 ppm dc (used with dc/lf calibrator
    • Frequency: DC to 10 kHz
    • Burden voltage (compliance): 4.5 V @ 120 A
    • Inductive drive capability: 1 mH load
    • Output ranges: 2 A, 20 A, 120 A
    • Input ranges: 2 V or 200 mA F.S. for 2 A and 20 A ranges, 1.2 V or 120 mA F.S. for 120 A range
    • Parallel operation: (Closed loop mode with 61XXX or 5730A) 2 or 3 amplifiers, up to 360 A in a single phase
    • Parallel operation: (Standalone mode), up to 10 amplifiers, up to 1200 A in a single phase
    • Accessory coils: 25-turn coil supports 3000 A, 50-turn coil supports 6000 A
    • Control communication with 6105A/6100B Electrical Power Standards or 5730A
    • GPIB remote operation
    The 52120A is designed for users whose ability to address their calibration workload may be
    limited by the output current, accuracy and drive capability of their present test equipment,
    including:
    • Calibration professionals in a calibration/standards lab or an electrical utility
    • Manufacturers of power/energy instrumentation and meters, power quality analyzers or power converters
    • Users of electrical test and measurement equipment

    The 52120A operates as a transconductance amplifier with:

    • 5522A/5502A/5520A/5500A Multi-Product Calibrators
    • 5730A*/5700A/5720A Multifunction Calibrator
    • 6105A*/6100B* Electrical Power Standard
    • 5080A Multi-Product Calibrator
    • 9100 Universal Calibration System
    • Any calibrator, signal generator or power supply capable of sourcing 2 V or 200 mA, dc or ac

    You may also operate your 52120A in closed-loop mode, seamlessly communicating with your Fluke Calibration 6105A or 6100B Electrical Power Standard to deliver enhanced 52120A accuracy.

    Operating limits
    Output ranges2 A, 20 A, 120 A (100 A dc)
    Input current range200 mA, 200 mA, 120 mA (100 mA dc)
    Current gain10, 100, 1000
    Input voltage range2 V, 2 V, 1.2 V (1.0 V dc)
    Transconductance1,10,100 Siemens
    FrequencyTo 10 kHz
    Maximum output compliance voltage4.5 Vrms (6.4 Vpeak)
    Inductive drive capability:1 mH load
    Output isolation, current terminal to earth600 Vrms, 850 Vpeak, dc to 850 Hz
    Performance specifications
    AC accuracy, closed loop with 6105ATo 140 ppm
    DC accuracy, standaloneTo 160 ppm
    AC accuracy, standaloneTo 350 ppm
    Phase angle accuracy0.006°
    Load dependent phase angle shift<0.001° @ 60 Hz
    General specifications
    Input line voltage range100 V to 240 V with up to ±10 % fluctuations
    Transient overvoltageImpulse withstand (overvoltage); Category II of IEC 60364-4-443
    Frequency47 Hz to 63 Hz
    Maximum consumption< 1500 VA
    Calibration DocumentationReport of calibration with data included; 17025 accredited report optional
    Dimensions with feet (H x W x L)192 mm x 432 mm x 645 mm
    (7.6 inches x 17 inches x 25.5 inches)
    Dimensions without feet (H x W x L)178 mm x 432 mm x 645 mm
    (7 inches x 17 inches x 25.5 inches)
    Weight25 kg (54 lb.)
    Design standards and complianceDesigned to EN 61010-1: 2010, CAN/CSA 22.2 No 61010.1-04, ANSI/UL 61010-1:2004, EN 61326-1:2006 CE marked, CSA listed
    Operating temperature5 °C to 35 °C
    Calibration temperature range16 °C to 30 °C
    Warm up time1 hour
    Safe operating max. relative humidity (non-condensing)<80 % 5 °C to 31 °C ramping linearly down to 50 % at 35 °C
    Operating altitude0 m to 2,500 m
    Shock and vibrationMIL-PRF-28800F class 3
    Specification confidence level99%

    FAQ:

    1.Can you ship order to Canada or Australia ?
    Yes,we can .We send orders worldwide .
    2. What delivery method do you use ? and delivery time ?
    We can ship by EMS,DHL,FedEx,UPS,TNT with tracking number. Usual delivery time is 4-7 workdays.
    3. What is your payment term?
    100% T/T payment before shipment.
    4. How can I ask any other question ?
    You can contact us online or leave us messages below.


    Fluke 52120A Transconductance Amplifier tested in full working conditionsFluke 52120A Transconductance Amplifier tested in full working conditionsFluke 52120A Transconductance Amplifier tested in full working conditionsFluke 52120A Transconductance Amplifier tested in full working conditions

    Fluke 52120A Transconductance Amplifier tested in full working conditions


    Quality Fluke 52120A Transconductance Amplifier tested in full working conditions for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Meigaolan Electronic Instrument Co. Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)