Sign In | Join Free | My himfr.com
Home > Vector Network Analyzer >

Agilent N5242A PNA X Vector Network Analyzer Microwave 26.5 GHz

Shenzhen Meigaolan Electronic Instrument Co. Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Agilent N5242A PNA X Vector Network Analyzer Microwave 26.5 GHz from wholesalers
     
    Buy cheap Agilent N5242A PNA X Vector Network Analyzer Microwave 26.5 GHz from wholesalers
    • Buy cheap Agilent N5242A PNA X Vector Network Analyzer Microwave 26.5 GHz from wholesalers
    • Buy cheap Agilent N5242A PNA X Vector Network Analyzer Microwave 26.5 GHz from wholesalers
    • Buy cheap Agilent N5242A PNA X Vector Network Analyzer Microwave 26.5 GHz from wholesalers
    • Buy cheap Agilent N5242A PNA X Vector Network Analyzer Microwave 26.5 GHz from wholesalers

    Agilent N5242A PNA X Vector Network Analyzer Microwave 26.5 GHz

    Ask Lasest Price
    Brand Name : Keysight (Agilent)
    Model Number : N5242A
    Payment Terms : T/T
    Price : Negotiation
    Supply Ability : in stock
    • Product Details
    • Company Profile

    Agilent N5242A PNA X Vector Network Analyzer Microwave 26.5 GHz

    Keysight Agilent N5242A PNA-X Microwave Network Analyzer 26.5 GHz


    Description of Keysight Agilent N5242A


    The PNA-X network analyzer is the world´s most integrated and flexible single-connection microwave test engine for measuring active devices such as amplifiers, mixers, and frequency converters. You can choose from five frequency models to meet your specific device test needs: 13.5, 26.5, 43.5, 50, and 67 GHz. The PNA-X provides unrivaled configurability with a built-in second source, combiner, and internal signal-routing switches.


    Overview and Features of N5242A PNA-X Microwave Network Analyzer

    • Reach for unrivaled excellence in your measurements and designs
    • Simplify your test stations by replacing racks and stacks of equipment
    • Increase productivity with the most integrated and flexible single-connection microwave test engine
    • Reduce test time with the world´s widest range of single-connection measurement applications
    • Test linear and nonlinear device characterization more accurately with the world’s best PNA-X

    Applications:

    • S-parameters (CW and pulsed)
    • Noise figure
    • Gain compression
    • Intermodulation and harmonic distortion
    • Conversion gain/loss
    • True-differential stimulus
    • Millimeter-wave
    • Nonlinear waveform and X-parameter® characterization
    • Antenna test

    Features:

    • 10 MHz to 26.5 GHz
    • 2- or 4-ports with two built-in sources
    • 132 dB system and 130 dB receiver dynamic range, 32,001 points, 32 channels, 5 MHz IF bandwidth
    • High output power (+18 dBm), low harmonics (-60 dBc) and a wide power sweep range (38 dB)
    • Best dynamic accuracy: 0.1 dB compression with +13 dBm input power at the receiver
    • Low noise floor of -114 dBm at 10 Hz IFBW
    List of Options
    007Automatic Fixture Removal
    008Pulsed-RF measurements
    010Time-domain measurements
    014Configurable Test Set Option (front panel access loops between source output and coupler input) Standard Option
    016Add Reciever Attenuators (35 dB in 5 dB steps)(Standard Option)
    020Add IF inputs
    021Add pulse modulator to internal first source
    022Add pulse modulator to internal second source
    025Add four internal pulse generators
    028Noise figure measurements using standard receivers
    029Fully-corrected noise-figure measurements to 26.5 GHz
    080Frequency offset measurements
    081Reference Channel Switch (Adds internal switch to R1 Path)(Standard Option w/080)
    082Scalar calibrated converter measurements
    083Vector and scalar calibrated converter measurements
    084Embedded LO measurements
    086Gain compression application
    087Intermodulation distortion measurements
    088Source phase control
    090Spectrum Analyzer
    118Fast CW mode
    1A7ISO 17025 compliant calibration
    1CMRack mount kit for installation without handles
    1CPRack mount kit for installation with handles
    2002 ports, single source
    219Add extended power range and bias-tees to 2 port analyzer
    224Add internal second source, combiner and mechanical switches to 2-port analyzer
    285Add extended power range to 2 port analyzer (no bias tees.
    301Application for use with standard CalPods
    302Application for use with temperature-characterized CalPods
    4004 ports, dual source
    419Add extended power range and bias-tees to 4 port analyzer
    423Add internal combiner and mechanical switches to 4-port analyzer
    460Integrated true-mode stimulus application
    485Add extended power range to 4 port analyzer (no bias-tees)
    510Nonlinear Component Characterization
    514Nonlinear X-Parameters
    518Nonlinear Pulse Envelope Domain
    520Arbitrary load impedance X-parameters
    551N-port calibrated measurements
    629Noise figure accessories
    897Built-in performance test software for Agilent inclusive calibration, perpetual license
    898Built-in performance test software for standards compliant calibration, perpetual license
    A6JANSI Z540 compliant calibration
    H08Pulsed - RF measurments
    H85Removes bias tees between source attenuators and test port couplers
    N1966APulse/IO Adapter
    N8981ASpare hard drive for use with 1.1 GHz Pentium M CPU board Recommended for use in secure environments
    P044 Ports Native
    PS-S10Remote scheduled productivity assistance. Select 1 to 999 hours.
    PS-S20Startup assistance
    PS-S20-01Recommended Startup assistance
    PS-T10-PNAPNA operator training for 8 students at the customer's site , H7215B-203
    PS-T12-PNAPNA programming for 8 students at the customer's site , H7215B-204
    R-50C-011-3Agilent Calibration - 3 years
    R-50C-011-5Agilent Calibration - 5 years
    R-50C-016-3ISO 17025 Compliant Calibration - 3 years
    R-50C-016-5ISO 17025 Compliant Calibration - 5 years
    R-50C-021-3ANSI Z540-1-1994 Calibration - 3 years
    R-50C-021-5ANSI Z540-1-1994 Calibration - 5 years
    R-50J-001-3Onsite System Verification - 3 years
    R-50U-001-3Onsite Agilent Calibration - 3 years
    R-50U-002-3Onsite ANSI Z540-1-1994 Calibration - 3 years
    R-51B-001-3CReturn to Agilent Warranty - 3 years
    R-51B-001-5CReturn to Agilent Warranty - 5 years
    R-51B-001-CReturn to Agilent Warranty - 1 year
    R-51C-001-1CUOnsite Warranty - 1 year
    R-51C-001-3CUOnsite Warranty - 3 years
    S02Second Source Module
    UK6Commercial calibration certificate with test data
    UNLHigh Power Measurement w/ Bias tees Configuration (Allows Ext. Amplifiers between RF Source and Coupler Input)(Standard Option)
    Win7Windows 7 Operating System
    WXPWindows XP OS

    FAQ:

    1.Can you ship order to Canada or Australia ?

    Yes,we can .We send orders worldwide .

    2. What delivery method do you use ? and delivery time ?

    We can ship by EMS,DHL,FedEx,UPS,TNT with tracking number. Usual delivery time is 4-7 workdays.

    3. What is your payment term?

    100% T/T payment before shipment.

    4. How can I ask any other question ?

    You can contact us online or leave us messages below.


    Agilent N5242A PNA X Vector Network Analyzer Microwave 26.5 GHz


    Agilent N5242A PNA X Vector Network Analyzer Microwave 26.5 GHz

    Agilent N5242A PNA X Vector Network Analyzer Microwave 26.5 GHz


    Quality Agilent N5242A PNA X Vector Network Analyzer Microwave 26.5 GHz for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Meigaolan Electronic Instrument Co. Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)